10TR Industrial Water Chiller 10Ton Air Cooled Scroll Chiller 10kW Cooling System

Brand Name : ANGES/SZAGS

Model Number : ACK-10(D)

Certification : CE/ISO9001

Place of Origin : China

MOQ : 1

Price : Negotiatible

Payment Terms : T/T, MoneyGram

Supply Ability : 600 sets/ month

Delivery Time : 10-35 days

Packaging Details : Plywood case

Type : Air Cooled Sroll Type

Capacity : 10HP/10TR

Compressor typetype : Danfoss/Panosonic/Copeland/LG

Refrigerant : R410A/R407C/R134A/R22

Condenser : finned copper tube + low noise outer rotor fan

Water tank : 85L/170L

Voltage : 3PH~220V/380/415V~50HZ/60HZ

Dimension(l*w*h) : 1530*780*1630

Weight : 500kg

Temperature range : 5℃ ~ 35℃

Application : Industrial Cooling Solutions,Plastic & rubber / Chemical etc / Welding

Compressor type : Scroll type

Water Pump : 2~4 Bar(included)

After-sales provided : 24hours Online support/Video technical support/Overseas third-party support available and etc.

Contact Now

10 Ton Air Cooled Water Chiller 10HP Water Cooled Chiller Industrial Water Chiller High Efficiency Chiller System For Injection Molding Machine

Air-cooled Chiller

Air-cooled industrial chillers from 1kw to 222kw equipped with world class components, including high efficiency scroll compressor. They use ambient air to cool the refrigerant to help keep your industrial processes running strong. Air-cooled chillers are stand-alone units and do not require any additional equipment to function.

Specification

Model

Item

ACK-10(D)
nominal cooling capacity kcal/h 24940
kw 29
input power kw 11.22
power supply 3PH 380V 50HZ
refrigerant type R407C
type of control thermostatic expansion valve
compressor type hermetic scroll
power(kw) 8.8
condenser type finned copper tube + low noise outer rotor fan
cooling air flow(m3/h) 10000
evaporator type shell and tube
chilled fluid flow(m3/h) 5
volume(L) 85
inlet and outlet pipe diameter(inch) 1-1/2
pump power(kw) 1.5
lift(m) 20
safety protection compressor overheating protection, over-current protection, high and low pressure protection, over-temperature protection,flow switch protection, phase sequence or missing phase protection, exhaust overheating protection
weight kg 500
dimension mm 1530*780*1630

Note: The nominal cooling capacity is according to: Inlet chilled fluid temperature: 17℃,outlet chilled fluid temperature: 12℃.

Installation&Maintenance

Maintenance: Air-cooled chillers eliminate the need for cooling towers and no need water treatment, chiller condenser-tube cleaning, tower mechanical maintenance.

Installation: Most of the air-cooled chillers are packed systems which are including the air-cooled finned condenser, evaporator compressor and evaporator.Some of them are built-in water storage tank and pump,they are designed and configured at the factory for optimal performance and reliability, which reduces design and simplifies installation.

About ANGES/SZAGS Chiller

1. All the chillers are provided with 12 months free maintenance service.
2. Chiller maintenance service outside the warranty period, life-long tracking maintenance, cost price to provide equipment parts.
3. Provide technical explanation, chiller debugging support, technical training and chiller maintenance guidance.
4. If necessary, after-sales engineers can be on-site service confirmed by both parties through communication .In some areas, local dealers can provide fast and convenient service.
5. Provide the air chiller and water chiller required parts quickly to ensure the normal use of customers.If necessary, part of the wearing parts can be provided for backup after confirmation by both parties.

FAQ

1.How does a chiller system work?

The chiller operates with two circulations: one involves the circulation of process water, while the other entails the circulation of refrigerant gas. Heat absorbed from the process is transferred to the refrigerant circulation, and then expelled to either air or water.

2.How to calculate cooling capacity for chillers?

Cooling Capacity(kw)= Flow Rate(m3/h)*Temp Change(T1-t2)/0.86

Heat Load= C(specific heat)* M(quality output per hour )*Temp Change(T1-T2)


Product Tags:

10Ton Industrial Water Chiller

      

10kW Industrial Water Chiller

      

10TR Industrial Water Chiller

      
China 10TR Industrial Water Chiller 10Ton Air Cooled Scroll Chiller 10kW Cooling System wholesale

10TR Industrial Water Chiller 10Ton Air Cooled Scroll Chiller 10kW Cooling System Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Anges Machinery Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)