100HP Air Cooled Screw Compressor Chiller Industrial chemical chiller For Pvc PE PP Pipe Ex

Brand Name : ANGES

Model Number : 100HP

Place of Origin : China

MOQ : 1

Payment Terms : T/T, L/C

Delivery Time : 30 days

Packaging Details : Plywood case

Condition : Brandnew

Warranty : 1-year

Voltage : 3PH~220V/380/415V~50HZ/60HZ

Cooling capacity : 100 ton

Compressor type : Semi-hermetic screw

Evaporator : Shell and tube

Condenser : Aluminum finned copper tube + axil fan

Refrigerant : R134a/R407C/R22

Contact Now

100HP Air Cooled Screw Compressor Chiller Industrial chemical chiller 100 Ton Air cooling machine for Pvc PE PP Pipe Extruder.

An extruder is a plastic molding equipment. Mainly used for various extruded plastic products, such as PE, PP, PVC, ABS, etc. The high temperature generated during the production process will cause difficulty in demoulding and slow molding, so a cooling water system (pool, cooling tower, chiller) is required. Takes away heat from the extruder.

Model

Parameter

AGS-100ASH
nominal cooling capacity kcal/h 281134
kw 326.9
input power kw 107
Max. Running current A 243.9
power supply 3PH~380V/50HZ
refrigerant type R22
refrigerating circuit 1
type of control thermostatic expansion valve
compressor type semi-hermetic screw
quantity 1
Power 89
start-up mode Y-△
capacity control 0-25-50-75-100
condenser type air cooled type finned copper tube
cooling air flow (m3/h) 105000
power(kw) 18
evaporator type shell and tube
quantity 1
chilled fluid flow (m3/h) 56.2
inlet and outlet pipe diameter (inch) 4
safety protection compressor over temperature, unit overload, high and low pressure, flow switch, phase sequence, phase-missing, anti-freezing
net weight kg 2860
Dimension mm 4400*1890*2420

When the temperature of the chiller is too high, it may be caused by a variety of reasons, which need to be systematically checked and handled. The following are common reasons and solutions for reference:
Insufficient cooling water flow

Possible reasons: water pump failure, pipe blockage, dirty filter blockage, valve not fully open.

Solution:

Check whether the water pump is operating normally (listen for abnormal sounds, measure current).

Clean impurities in the filter or pipe.

Confirm that the valve is fully open.

Insufficient or leaking refrigerant

Possible reasons: System leakage leads to reduced refrigerant and reduced cooling efficiency.

Solution:

Check the pressure gauge. If the pressure on the low-pressure side is too low, check the leak and add refrigerant (professional operation is required).

Poor heat dissipation of the condenser

Possible reasons:

Air-cooled: dust accumulation on the condenser fins, fan failure or poor environmental ventilation.

Water-cooled: low cooling tower efficiency and poor water quality lead to scaling.

Solution:

Clean the condenser fins or cooling tower fillers.

Check whether the fan/water pump is normal and improve the ventilation environment.

Water-cooled type needs to be descaled or replaced regularly.

Compressor overload or failure

Possible reasons: unstable power supply voltage, compressor wear, insufficient lubricating oil.

Solution:

Check whether the voltage is stable and adjust the power supply line.

Listen for abnormal noise from the compressor and measure whether the operating current exceeds the limit.

Contact the manufacturer to repair or replace the compressor.

Ambient temperature is too high

Possible reasons: poor ventilation at the installation location of the chiller or the ambient temperature exceeds the design range.

Solution:

Add exhaust fans or adjust the location of the equipment to ensure heat dissipation space.

In high temperature environments, awnings or temporary cooling equipment can be installed.

Control system failure

Possible reasons: temperature sensor failure, controller parameter setting error.

Solution:

Calibrate or replace the temperature sensor.

Check the controller setting value (such as target temperature, differential pressure protection value).

The benefits of using air-cooled chillers:

  1. No cooling towers.
  2. Better environmental stability-no water wastage.
  3. Low maintenance costs.
  4. Easier to operate and control-tower freezing and tower bypass absent.
  5. Chemical costs avoided.
  6. Water costs avoided, especially in cities.






China 100HP Air Cooled Screw Compressor Chiller Industrial chemical chiller For Pvc PE PP Pipe Ex wholesale

100HP Air Cooled Screw Compressor Chiller Industrial chemical chiller For Pvc PE PP Pipe Ex Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Anges Machinery Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)